Requirements of subsurface:

  • Concrete quality min. C20/25 DIN EN 206-1 cracked and uncracked
  • Concrete thickness min. 160 mm
  • Distance from concrete edge min. 300 mm

  Mounting materials:

  • FIS SB 390-S injection mortar

  Standards / Approval / Number of users:

  • DIN EN 795:2012 Type A for 1 person
  • CEN/TS 16415:2013 for 4 people
  • DIBt approval Z-14.9-725

 

Support height For roof height Item no.
500 mm up to 350 mm 46150000