Fall protection

Products

SAFEX ESE LIGHT

Stainless steel anchorage point for fitting to concrete, wood and steel facades

Montageanleitung

Sicherheitshinweise

Ausschreibungstext

Ausschreibungstext kleben

Zertifikat

PDF

Requirements of subsurface / mounting materials:

  • for reinforced concrete: for gluing into solid concrete min. C20/25, min. 125 mm deep gluing with FIS V360 S two-component injection mortar
  • for wooden beams: for bolting through solid wood (min. 13 x 10 cm), incl. 2 x M16 wood gripping washers
  • for steel girders: for bolting through min. 5 mm thick steel subsurface (min. 30 mm distance to edge) Height of roof structure: max. 200 mm projection above fixing surface

  Standards / Approval / Number of users: EN 795: 1996 Class A for 3 people  

Support height Item no.
125 mm 49521 0000
200 mm 49522 0000
300 mm 49523 0000
400 mm 49524 0000
500 mm 49525 0000
600 mm 49526 0000
700 mm 49527 0000