Anchorage point with swivel eye bolt.
The specification text is only available on request.
Minimum requirements for mounting surface:
Concrete
reinforced standard concrete (cracked and uncracked) | DIN EN 206-1/A2 |
Strength class | C20/25 bis C50/60 |
Minimum component thickness hmin | 120 mm |
Edge distance dowel cmin – transverse load | 150 mm |
Edge distance dowel cmin – vertical load | 100 mm |
Metal
Steel | DIN EN 1993-1-1 |
Strength class | ≥ S235 |
Minimum component thickness tmin (mm) | Tech. building regulations min. 5 mm |
Edge distance cmin (mm) | Tech. building regulations |